Model 2016 consists of thermocouple type ammeters and voltmeters with four different measurement ranges. They are designed to provide true RMS values of inputs, so they can be used to measure high-frequency currents and voltages (DC) up to several MHz (the maximum frequency for the voltmeter is 100 kHz). The indicator is based on a taut-band suspension system, which eliminates friction, provides good resistance to vibrations and shock impact, and ensures excellent characteristics.

Specifications - Model 2016 01

Max. Scale Value 5/10/20/50 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 5 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 02

Max. Scale Value 20/50/100/200 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 2 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 03

Max. Scale Value 100/200/500/1000 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 1 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 04

Max. Scale Value 15/30/75/150 V
Approximate Consumed Current 5 mV (200 Ω/V)
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 1 kHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 195 x 170 x 87 mm
Approx. External Weight 1.8 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies
 
ModelDescription
2016 01 5/10/20/50 mA, 375 mV, 10 Hz to 5 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 02 20/50/100/200 mA, 375 mV, 10 Hz to 2 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 03 100/200/500/1000 mA, 375 mV, 10 Hz to 1 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 04 15/30/75/150 V, 5 mV (200 ?/V), 10 Hz to 1 kHz, 195 x 170 x 87 mm, 1.8 kg

Location